Any existing terms and agreements will be taken into account when processing your order.

Tyco HX-SCE markers

click here to download a pdf version of this page

HX-SCE – High performance Low Fire Hazard identification solution

Thin wall, zero-halogen, low smoke, low toxicity, radiation cross-linked, UV stablised polyolefin heatshrinkable tubing, assembled as cut sleeves organised in a ladder format.

Identification of wires and cables by computer-based printing onto sleeves. Ideal for applications where limited fire hazard characteristics are critical. The zero halogen material coupled with low smoke and low toxic fume emissions made this product ideal for use in enclosed spaces such as mass transit, marine and industrial installations. This product is not recommended where strain relief properties are required.

Features and benefits
  • Low fire hazard properties, low smoke, low toxicity, low flammability – meets Industry Standard BS6853 (1999) Vehicle Category 1a, NF F 16-101, DIN 5510-2 and CEI 20-37-7 09-1997

  • Superb print quality to give crisp clear identification marker sleeve

  • Excellent print permanence when tested in demanding industry related fluids to Industry Standard EN50343

  • Choice of printer options

  • Sleeve diameters from 2.4mm to 38.1mm

  • Sleeves are printable on both sides for ease of identification or addition of additional information to the marker sleeve

    Dimensions are shown for reference purposess only.
    Conversion rate: 25.5mm = 1 inch
    Dimensions are in inches and millimetres unless otherwise specified. Values in brackets are metric equivalents.

    Specifications subject to change.



  • Part numbering system


    Ordering information



    Available sizes and formats

    Part No. D (min) as Supplied d (max) After Recovery Recommended Use Range Pack Qty
      mm inches mm inches mm inches  
    HX-SCE-1K-2.4-50 (colour) 2.40 0.094 1.19 0.047 1.75 - 2.66 0.069 - 0.105 100
    HX-SCE-1K-3.2-50 (colour) 3.20 0.126 1.58 0.060 2.54 - 4.06 0.100 - 0.160 100
    HX-SCE-1K-4.8-50 (colour) 4.80 0.189 2.36 0.090 3.81 - 5.46 0.150 - 0.215 100
    HX-SCE-1K-6.4-50 (colour) 6.40 0.250 3.18 0.125 5.59 - 8.12 0.220 - 0.320 100
    HX-SCE-1K-9.5-50 (colour) 9.50 0.375 4.75 0.187 6.99 - 10.79 0.275 - 0.425 100
    HX-SCE-1K-12.7-50 (colour) 12.70 0.500 6.35 0.250 10.16 - 16.25 0.400 - 0.640 100
    HX-SCE-1K-19.0-50 (colour) 19.00 0.730 9.53 0.375 14.29 - 21.59 0.563 - 0.850 100
    HX-SCE-1K-25.4-50 (colour) 25.40 1.000 12.70 0.500 20.95 - 33.02 0.825 - 1.300 100
    HX-SCE-1K-38.1-50 (colour) 38.10 1.500 19.05 0.750 14.29 - 21.59 0.563 - 0.850 100



    Options
    Prescoring Perforated score to produce multiple marke sleeves from each HX-SCE sleeve
      Number of prescores: 1 prescore 2 prescores 3 prescores  
      Code: S1 S2 S3  
    Package sizes Standard: 1K – 1000 piece packages available for all HX-SCE sizes
        2.5K – 2500 pieces available for 4.8 and 6.4 HX-SCE sizes
        5K – 5000 pieces available for 2.4 and 3.2 HX-SCE sizes
    Colours Standard: Yellow White    
        4 9    
      Non Standard: Red Orange Green Blue
        2 3 5 6
    Ordering Information Reference pack size, product diameter, sleeve length, prescores and colour then reference part numbering system.



    Technical Information
    Print Method/Ribbon: T312M-Printer with 1966-ribbon or T212M-Printer with T200-1966-ribbon
    Service Temperature: -30ºC to +105ºC (-22ºF to +221ºF)
    Minimum Shrink Temperature: 135ºC (275ºF)
    Colours: White or yellow. Other colours available on request
    Flammability: Self-extinguishing (ASTM D2671 procedure B)
    Oxygen Index: 34% minimum (BS EN ISO 4589-2 [1996])
    Smoke Emission A: 0.017 maximum (BA 6853 [1999] Annex D.8.3)
    Toxic Fume R: <1 (BS 6853 [1999] Annex B – Mass based test method – NF X 70-100)
    LUL toxic Fume: No halogens, no P, S, or N sources above trace level (LUL E1042:A6 [2002])
    Dielectric Strength: 15kV/mm minimum
    Water Absorbsion: 1% maximum after 24 hours at 23ºC (73ºF)
    Copper Mirror Corrosion: 8% maximum after 16 hours at 150ºC (302ºF)
    Longitudinal change: +5% to -10%
    Tensile Strength: 7MPa minimum
    Ultimate Elongation: 80% minimum
    Secant Modulas: 200MPa maximum at 2% elongation
    UV Resistance: (base polymer) Tensile strength >90% & Ultimate elongation >40% of original value after 1000 hours (ASTM G53: UVA [100% dry cycle]; UVB [8 hours dry/4 hours wet cycle])
    Print Permanence: Adherence – meets the requirements of SAE AS81531 4.6.2 (50 rubs). Fluid Resistance – meets the requirements of MIL-STD-202F method 215J



    Fluid Resistance
    Threat Test Effect
    Xylene/butylacetate/cyclohexanone mix (Paint Stripper) 10 wipes dry tissue Print Contrast >/8
    Locomotive diesel 10 wipes dry tissue Print Contrast >/8
    Tunnel dust/white spirits LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Water LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Tunnel Dust and Oil (50%/50%) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Tunnel Dust and Water (50%/50%) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    White Spirit LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Diesel LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Grease LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Glycol rail de-icer (50% glycol / 50% water) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Cleaning solvent LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Surface Cleaner (PGP500) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    Multi-Purpose Graffiti remover gel LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    CGR gel (Chewing gum remover) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8
    IRM 902 oil pr EN50343 (24 hours at 50ºC [122ºF]10 wipes) Print Contrast >/8
    Hydrochloric acid 5% solution pr EN50343 (1 minute at 23ºC [73ºF]10 wipes) Print Contrast >/8
    Sodium Hydroxide 5% solution pr EN50343 (1 minute at 23ºC [73ºF]10 wipes) Print Contrast >/8
    Heat aging pr EN50343 (240 hours at 120ºC 10 wipes) Print Contrast >/8
    Wash cycle test 25 cycles at 75ºC, 25 wipes Print Contrast >/8
    Aircraft fuel (ISO 1817 Liquid B) 24 hours at 40ºC (104ºF) then 25 strokes dry tissue; IEC 60684-2 Print Contrast >/8 4MPa TS & 90% UE retained
    Silicone fluid (S1714) 24 hours at 50ºC (122ºF) then 25 strokes dry tissue; IEC 60684-2 Print Contrast >/8 4MPa TS & 90% UE retained
    Propan-2-ol 24 hours at 23ºC (73ºF) then 25 strokes dry tissue; IEC 60684-2 Print Contrast >/8 4MPa TS & 90% UE retained
    De-icing fluid (50% ethylene glycol) 24 hours at 23ºC (73ºF) then 25 strokes dry tissue; IEC 60684-2 Print Contrast >/8 4MPa TS & 90% UE retained
    Sullage fluid (formaldehyde/crosol) 24 hours at 23ºC (73ºF) then 25 strokes dry tissue; IEC 60684-2 Print Contrast >/8 4MPa TS & 90% UE retained




    Index -> Rail Cable Marking Systems -> Tyco HX-SCE markers

    FREEFONE: 0800 0280134    FREEFAX: 0800 0280135

    Copyright © 2005 Cablecraft