Any existing terms and agreements
will be taken into account when processing your order.
|
click here
to download a pdf version of this page
AMP PIDG Restricted Entry Nylon Terminals,
Tools, Gauges and Strip Lengths matched to fit Thin Wall Rail
Industry Cables
| Cable
Type |
CSA
MM˛ |
Ins
Max Dia |
Terminal
Colour AWG |
AMP
Part Numbers |
| |
|
|
|
M3
Ring (6BA) |
M4
Ring (3BA) |
M5
Ring (2BA) |
M6
Ring (0BA) |
M8
Ring (5/16") |
Hand
Tool |
Strip
Length |
Pin
Setting |
Wire
Crimp Gauge |
| 19
/ 0.15 |
0.38 |
1.35 |
Red/Green 22 |
51863-2 |
1-320551-2 |
2-36153-3 |
2-320571-3 |
2-320572-2 |
47386
or 525690 |
6.4
to 7.1 |
1 |
574917 |
| 19
/ 0.20 |
0.62 |
1.92 |
Red/Red 20 |
51863-3 |
1-320551-3 |
2-36153-4 |
2-320571-4 |
2-320572-3 |
47386
or 525690 |
6.4
to 7.1 |
1 |
574917 |
| 19
/ 0.30 |
1.34 |
2.46 |
Blue/Blue 16 |
2-320561-3 |
1-51864-0 |
51864-7 |
2-320563-3 |
2-320572-2 |
47386
or 525690 |
6.4
to 7.1 |
1 |
574916 |
| 37
/ 0.25 |
1.8 |
2.59 |
Blue/Green 14 |
51864-8 |
1-51864-1 |
51864-9 |
2-320563-4 |
2-320575-3 |
47386
or 525690 |
6.4
to 7.1 |
1 |
574916 |
| 37
/ 0.30 |
2.6 |
3.07 |
Yellow/Yellow 12 |
2-36161-5 |
2-320568-2 |
2-36161-3 |
2-320569-5 |
2-320576-2 |
59239-4
or 525692 |
9.5
to 10.3 |
1 |
574915 |
| 37
/ 0.40 |
4.74 |
3.89 |
Yellow/Brown 10 |
2-36161-6 |
2-320568-3 |
2-36161-4 |
2-320569-6 |
2-320576-3 |
59239-4
or 525692 |
9.5
to 10.3 |
1 |
574915 |
AMP PIDG Nylon Terminals, Tools, Gauges
and Strip Lengths matched to fit Rail Industry Cables
| Cable
Type |
CSA
MM˛ |
Ins
Max Dia |
Terminal
Colour AWG |
AMP
Part Numbers |
| |
|
|
|
M3
Ring (6BA) |
M4
Ring (3BA) |
M5
Ring (2BA) |
M6
Ring (0BA) |
M8
Ring (5/16") |
| 37
/ 0.2 |
1.16 |
4.32 |
Blue Exp 16-14 |
326882 |
320565 |
130094 |
321045 |
328998 |
| If
the above terminals cause space problems these 22-16 red
terminals may be used provided that the completed termination
is adequately supported |
Red Exp 22-16 |
36152 |
31886 |
130008 |
130046 |
31895 |
| 37
/ 0.25 |
1.8 |
4.32 |
Blue Exp 16-14 |
326882 |
320565 |
130094 |
321045 |
328998 |
| If
the installation of the above blue terminal does not provide
adequate cable support within 150mm of the cable termination
then 16-14 Black terminals must be used |
Black 16-14HD |
342060 |
324061 |
342062 |
342063 |
342064 |
| 37
/ 0.3 |
2.6 |
5.83 |
Yellow Std 12-10 |
320567 |
320568 |
130167 |
320569 |
320576 |
| 37
/ 0.4 |
4.7 |
5.83 |
Yellow Std 12-10 |
320567 |
320568 |
130167 |
320569 |
320576 |
| 61
/ 0.4 |
7.7 |
7.6 |
Red Amplibond 8 |
|
|
322128 |
321669 |
322003 |
| 80
/ 0.4 |
10 |
7.6 |
Blue Amplibond 6 |
|
|
322050 |
322051 |
322006 |
AMP PIDG Nylon Terminals, Tools, Gauges
and Strip Lengths matched to fit Rail Industry Cables
| Cable
Type |
AMP
Part Numbers |
| |
M10
Ring (3/8") |
M12
Ring (1/2") |
Hand
Tool |
Strip
Length |
Pin
Setting |
Wire
Crimp Gauge |
| 37
/ 0.2 |
328999 |
328849 |
47387
or 525691 |
5.0
- 6.0 |
2 |
574916 |
| If
the above terminals cause space problems these 22-16 red
terminals may be used provided that the completed termination
is adequately supported |
150072-1 |
|
47386
or 525690 |
5.0
- 6.0 |
1 |
574917 |
| 37
/ 0.25 |
328999 |
328849 |
47387
or 525691 |
5.0
- 6.0 |
2 |
574916 |
| If
the installation of the above blue terminal does not provide
adequate cable support within 150mm of the cable termination
then 16-14 Black terminals must be used |
342065 |
|
59239-4
or 525692 |
6.0
- 7.0 |
1 |
574915 |
| 37
/ 0.3 |
160138 |
3342066 |
59239-4
or 525692 |
6.0
- 7.0 |
2 |
574915 |
| 37
/ 0.4 |
160138 |
331467 |
59239-4
or 525692 |
6.0
- 7.0 |
2 |
574915 |
| 61
/ 0.4 |
322004 |
331467 |
59974-1
+ 48752-1 |
8.0
- 9.0 |
1 |
576792 |
| 80
/ 0.4 |
32007 |
328463 |
59974-1
+ 48753-1 |
8.0
- 9.0 |
1 |
525171-3 |
|
FREEFONE: 0800 0280134 FREEFAX:
0800 0280135
Copyright © 2005 Cablecraft
|